Soil vapour remediation (selected examples)
Project
Contaminants
Location
Berlin
CHC
Multistage activated-Carbon-System, upstream gravel filter
Q=250 m³/h, 4 locations
Planning, installation, operation, self monitoring
reporting
Multistage activated-Carbon-System
Q=100 m³/h, 12 locations
Remote monitoring
Installation, operation, reporting
CHC, CIS-DCE, VC
Kassel-Bettenhausen
Groundwater remediation of oxygenate compounds
using extraction of soil vapour and groundwater
2 vacuum systems 500 m³/h
Groundwater remedation 10 m³/h
Planning, installation and operation
Oxygenate compounds
Stendell
Soil vapour extraction on 26 locations
Remediation using catalytic purification
Installation, operation, analytics
BTEX, phenols
Spremberg
Soil vapour extraction
Negative pressure
Operation, technical monitoring
CHC
Berlin
Soil vapour extraction on 6 locations
Remediation using activated-Carbon-Systems
Installation, operation
CHC
Marburg
Soil vapour extraction
Negative pressure
Remediation using activated-Carbon-Systems
Operation,  technical monitoring
CHC
Berlin
Airsparging (IAS)
Q=25 m³/h
Extraction Q=150 m³/h, p
abs= 850 mbar
Installation, operation
CHC
Stendal
Soil vapour extraction on 7 locations
Remediation using activated-Carbon-Systems
Extraction Q=120 m³/h, p
abs= 300 mbar
Installation, operation
BTEX
Berlin
Soil vapour extraction on 9 locations
Remediation using activated-Carbon-Systems
Extraction Q=180 m³/h, p
abs= 800 mbar
Installation, operation, monitoring
CHC
Jüterbog
Soil vapour extraction on 4 locations
Remediation using biofilters and activated-Carbon-Systems
Planning, installation, operation, monitoring
Naphthalene, BTEX,
Chlorbenzene
Berlin