ARGUS Umweltbiotechnologie GmbH
ARGUS-logo-web
Fotooben_web
Company
Services
Referenzes
Quality management
Contact
Impressum
Research
Back
Imprint/Terms and conditions
©  2016 ARGUS Umweltbiotechnologie GmbH
References
flagge-deutschland-flagge-button-18x18
Pumping tests (selected examples)
Back
Extent/services
Contaminants
Location
Berlin
CHC
Pumping Test carried out in several stages and continuous
Determination of the pollutants development and the range of the process, period of 4 weeks
Q = 10 m³/h  
Implementation
Forst/Lausitz
SVHH
2 Pumping Tests carried out 2 locations
Determination of the hydraulic characteristics as
Staged- and Long-term Test
Qmax.=15 m³/h
Implementation
Jüterbog
BTEX
GWL-Test carried out
Determination of the hydraulic characteristics
Q = max. 5 m³/h
Implementation
Berlin
BTEX
GWL-Test carried out
Determination of the hydraulic characteristics
Q = max. 5 m³/h
Implementation
Stadt Brandenburg
SVHH
3-Staged Well Test and GWL-Test
caried out at 3 different locations with in-situ deferrization
Determination of the hydraulic characteristics
Q = max. 20 m³/h
Implementation, Evaluation and Monitoring
Berlin
CFC
(R113, R123, R113A)
3-Staged Pumping Test carried out
Determination of the hydraulic characteristics
Q = max. 15 m³/h
Implementation and Monitoring
Pumping Test carried out in several stages and continuous
Determination of the pollutants development, period of 4 weeks
Q = 5 m³/h
Implementation
CHC
Berlin
Pumping Test carried out in several stages and continuous
Determination of the pollutants development and the range of the process
Q = 5 m³/h
Implementation
CHC
Pritzwalk
Pumping Test carried out (continuous)
Determination of the pollutants development, period of 4 weeks
Q = 25 m³/h
Implementation
Phenols
Hennigsdorf
Pumping Test carried out
Determination of the concentration of contaminants

Q = 3 m³/h, continuous operation
Implementation
SVHH, arsenic
Berlin